Quality Improvement in Clinical Laboratories: A Six Sigma Concept

Authors

  • Jawahar (Jay) Kalra Department of Pathology, College of Medicine, University of Saskatchewan and Royal Univer- sity Hospital, Saskatoon, Saskatchewan, Canada
  • Ashish Kopargaonkar College of Pharmacy and Nutrition, University of Saskatchewan, Saskatoon, Saskatchewan, Canada

DOI:

https://doi.org/10.17140/PLMOJ-1-104

Keywords:

Quality healthcare, Clinical laboratories, Six sigma, Medical errors, Culture of safety, Quality management

Abstract

The quality of healthcare is an emerging concern worldwide. The term “Quality” has
been appropriately defined and fairly well understood. However, many problems in delivering
quality healthcare persist and these require urgent attention and solutions. An industrial grade
quality performance is still a distant dream in the healthcare sector. There are a variety of
reasons for this, chiefly the complexity of medicine and disease itself. An error rate as high as
9.36% has been reported in clinical laboratories. These errors mainly occur in the pre-analytical
stage of testing. Modern quality management tools like the six sigma concept offer realistic
solutions to reach practical levels of perfection. The response of clinical diagnostic laboratories
has been very slow in adopting these techniques to improve the quality of a process. It is
imperative that healthcare in general and clinical diagnostic laboratories in particular promote
and develop a culture of safety with the aid of modern quality management tools.

References

Kohn LT, Corrigan JM, Donaldson MS eds; Committee on Quality of Healthcare in America, Institute of Medicine. To Err is Human: Building a Safer Health System. Washington DC, USA: National Academy Press, 2000.

Kalra J. Medical errors: an introduction to concepts. Clin Biochem. 2004; 37: 1043-1051. doi: 10.1016/j. clinbiochem.2004.08.007

Kalra J. Medical errors: impact on clinical laboratories and other critical areas. Clin Biochem. 2004; 37: 1052-1062. doi: 10.1016/j.clinbiochem.2004.08.009

American National Standards Institute (ANSI)/ISO/American Society for Quality (ASQ) Q9000-2000, American National Standard, “Quality Management Systems – Fundamentals and Vocabulary”, 13 December 2000, Clause 3.1.1.

McLoughlin V, Leatherman S. Quality or financing: what drives design of the health care system? Qual Saf Health Care 2003; 12:136-142.

Lohr KN, ed. Institute of Medicine. Medicare: A Strategy for Quality Assurance. Vol. 1. Washington, D.C.: National Academy Press, 1990.

Donaldson LJ, Gray JA. Clinical governance: a quality duty for health organisations. Qual Health Care. 1998; 7 Suppl: S37- 44.

Anderson G, Hussey PS. Comparing health system performance in OECD countries. Organization for Economic Cooperation and Development. Health Aff (Millwood). 2001; 20: 219-232. doi: 10.1377/hlthaff.20.3.219

Chassin MR, Galvin RW. The urgent need to improve health care quality. Institute of Medicine National Roundtable on Health Care Quality. JAMA. 1998; 280: 1000-1005. doi:

1001/jama.280.11.1000 10. Crook M. Clinical governance and pathology. J Clin Pathol. 2002; 55: 177-179.

Scally G, Donaldson LJ. The NHS’s 50 anniversary. Clinical governance and the drive for quality improvement in the new NHS in England. BMJ. 1998; 317: 61-65. doi: 10.1136/ bmj.317.7150.61

Lanham B, Maxson-Cooper P. Is Six Sigma the answer for nursing to reduce medical errors and enhance patient safety? Nurs Econ. 2003; 21: 39-41, 38.

Harry MJ. “Six Sigma: A Breakthrough Strategy for Profitability.” Quality Progress. 1998; 31(5): 60-64.

Eichhorn JH. Prevention of intraoperative anesthesia accidents and related severe injury through safety monitoring. Anesthesiology. 1989; 70: 572-577.

Johnstone PA, Hendrickson JA, Dernbach AJ et al. Ancillary services in the health care industry: is Six Sigma reasonable? Qual Manag Health Care. 2003; 12: 53-63.

Harry M, Schroeder R. Six Sigma: The Breakthrough Management Strategy Revolutionizing the World’s Top Corporations. New York, USA: A Currency Book, Published by Doubleday; 2000.

Lamham B. Beth Lanham on Six Sigma in healthcare. Interview by Luc R. Pelletier. J Health Qual. 2003; 25: 26-7, 37.

Shewart WA. Economic control of quality of manufactured product. New York, USA: D Van Nostrand Company; 1931. (Reprinted by ASQC Quality Press, 1980).

Mohammed MA, Cheng KK, Rouse A, Marshall T. Bristol, Shipman, and clinical governance: Shewhart’s forgotten lessons. Lancet. 2001; 357: 463-467. doi: 10.1016/S0140- 6736(00)04019-8

Scalise D. Six sigma. The quest for quality. Hosp Health Netw. 2001; 75: 41-46, 2.

Scalise D. Six sigma in action. Case studies in quality put theory into practice. Hosp Health Netw. 2003; 77: 57-62.

Pande PS, Neuman RP, Cabanagh RR. The Six Sigma Way: How GE, Motorola and Other Top Companies are Honing Their Performance. New York, USA: McGraw-Hill; 2000: 5.

Haider SI. ISO 9001:2000 Initiatives. In: ReVelle JB, ed. Manufacturing Handbook of Best Practices: an innovation, productivity, and quality focus. Boca Raton, FL, USA: St. Lucie Press; 2002: 107-22.

Kotlarz VR. Tracing our roots: the broadening horizons of clinical laboratory practice (1945-62). Clin Lab Sci. 1998; 11: 339-345.

Plebani M. The changing face of clinical laboratories. Clin Chem Lab Med. 1999; 37: 711-717. doi: 10.1515/ CCLM.1999.109

Levey S, Jennings ER. The Use of Control Charts in the Clinical Laboratory. Am J Clin Pathol. 1950; 20: 1059-1066.

Witte DL, VanNess SA, Angstadt DS, Pennell BJ. Errors, mistakes, blunders, outliers, or unacceptable results: how many? Clin Chem. 1997; 43: 1352-1356.

Plebani M, Carraro P. Mistakes in a stat laboratory: types and frequency. Clin Chem. 1997; 43: 1348-1351.

Nevalainen D, Berte L, Kraft C, Leigh E, Picaso L, Morgan T. Evaluating laboratory performance on quality indicators with the six sigma scale. Arch Pathol Lab Med. 2000; 124: 516-519.

McSwiney RR, Woodrow DA. Types of error within a clinical laboratory. J Med Lab Techno. 1969; 26: 340-346.

Chambers AM, Elder J, O’Reilly DS. The blunder-rate in a clinical biochemistry service. Ann Clin Biochem. 1986; 23: 470- 473.

Kazmierczak SC, Catrou PG. Laboratory error undetectable by customary quality control/quality assurance monitors. Arch Pathol Lab Med. 1993; 117: 714-718.

Lapworth R, Teal TK. Laboratory blunders revisited. Ann Clin Biochem. 1994; 31: 78-84.

Khoury M, Burnett L, Mackay MA. Error rates in Australian chemical pathology laboratories. Med J Aust. 1996; 165: 128- 130.

Wilson RM, Runciman WB, Gibberd RW, Harrison BT, Newby L, Hamilton JD. The Quality in Australian Health Care Study. Med J Aust. 1995; 163: 458-471.

Hofgartner WT, Tait JF. Frequency of problems during clinical molecular-genetic testing. Am J Clin Pathol. 1999; 112: 14-21.

Wiwanitkit V. Types and frequency of pre-analytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 - month monitoring. BMC Clin Pathol. 2001; 1: 5-9. doi: 10.1186/1472-6890-1-5

Bonini P, Plebani M, Ceriotti F, Rubboli F. Errors in laboratory medicine. Clin Chem. 2002; 48: 691-698.

Ismail AA, Walker PL, Barth JH, Lewandowski KC, Jones R, Burr WA. Wrong biochemistry results: two case reports and observational study in 5310 patients on potentially misleading thyroid-stimulating hormone and gonadotropin immunoassay results. Clin Chem. 2002; 48: 2023-2029.

Marks V. False-positive immunoassay results: a multicenter survey of erroneous immunoassay results from assays of 74 analytes in 10 donors from 66 laboratories in seven countries. Clin Chem. 2002; 48: 2008-2016.

Westgard JO, Klee GG. Quality Assurance. In: Tietz NW, ed. Fundamentals of Clinical Chemistry, 3rd ed. Philadelphia, PA, USA: W.B. Saunders Co.; 1987: 238-253.

Grannis GF, Grumer HD, Lott JA, Edison JA, McCabe WC. Proficiency evaluation of clinical chemistry laboratories. Clin Chem. 1972; 18: 222-236.

Goldschmidt HMJ, Lent RW. Gross Errors and Workflow Analysis in the Clinical Laboratory. Klin Biochem Metab. 1995; 3: 131-140.

South SF, Casina TS, Li. L. Exponential error reduction in pretransfusion testing with automation. Transfusion. 2012; 52: 81S-87S. doi: 10.1111/j.1537-2995.2012.03816.x

St-Louis P. Status of point-of-care testing: promise, realities, and possibilities. Clin Biochem. 2000; 33: 427-440. doi: 10.1016/ S0009-9120(00)00138-7

Vanker N, Van Wyk J, Zemlin AE, Erasmus RT. A Six Sigma approach to the rate and clinical effect of registration errors in a laboratory. J Clin Pathol. 2010; 63: 434-437. doi: 10.1136/ jcp.2009.072058

Elbireer A, Le Chasseur J, Jackson B. Improving laboratory data entry quality using Six Sigma. Int J Health Care Qual Assur. 2013; 26: 496-509. doi: 10.1108/IJHCQA-08-2011-0050

Kalra J, Mulla A, Nayar A, Massey K.L, Saxena A. Quality Improvement: A Model for Clinical Diagnostic Laboratories. Clinical and Investigative Medicine. 2004. 27: 178.

Kalra J. Medical errors: overcoming the challenges. Clin Biochem. 2004; 37: 1063-1071. doi: 10.1016/j. clinbiochem.2004.08.008

Downloads

Published

2016-02-19

How to Cite

Jawahar (Jay) Kalra, & Ashish Kopargaonkar. (2016). Quality Improvement in Clinical Laboratories: A Six Sigma Concept. Pathology and Laboratory Medicine, 1(1), 11–20. https://doi.org/10.17140/PLMOJ-1-104