Effects of Iterative Reconstruction on the Diagnostic Assessment of Coronary Calcium Scores

Crossmark: check for updates

Authors

  • Zhonghua Sun Department of Medical Radiation Sciences, Curtin University, GPO Box U1987 Perth, Western Australia 6845, Australia

DOI:

https://doi.org/10.17140/HROJ-2-125

Keywords:

Coronary calcium score; Coronary artery disease, Diagnosis; Calcified plaque, Image processing, Iterative reconstruction.

Abstract

Coronary Artery Calcium (CAC) score is a widely used indicator to determine disease severity
and predict the risk of severe cardiac events. However, radiation dose associated with coronary
CT scanning for CAC scoring raises concerns, especially for asymptomatic patients.
Iterative Reconstruction (IR) technique represents a recently developed image processing
approach for reduction of image noise and radiation dose, while improving diagnostic image
quality. Despite these advantages over conventional filtered back projection technique, effects
of IR techniques on CAC scores remain unclear. This review article aims to provide an
overview of clinical applications of IR techniques in coronary CT angiography with a focus
on the effects of different IR techniques on CAC score assessment.

References

Greenland P, Bonow RO, Brundage BH, et al. ACCF/AHA 2007 clinical expert consensus document on coronary artery cal-cium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain: a report of the American College of Cardiology Foundation Clini-cal Expert Consensus Task Force (ACCF/AHA Writing Commit-tee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) developed in collaboration with the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography. J Am Coll Cardiol. 2007; 49(3): 378-402. doi: 10.1016/j.jacc.2006.10.001

Arad Y, Spadaro LA, Goodman K, Newstein D, Guerci AD. Prediction of coronary events with electron beam computed tomography. J Am Coll Cardiol. 2000; 36(4): 1253-1260. doi: 10.1016/S0735-1097(00)00872-X

Greenland P, LaBree L, Azen SP, Doherty TM, Detrano RC. Coronary artery calcium score combined with Framingham score forrisk prediction in asymptomatic individuals. JAMA. 2004; 291(2): 210-215. doi: 10.1001/jama.291.2.210

Taylor AJ, Bindeman J, Feuerstein I, Cao F, Brazaitis M, O’Malley PG. Coronary calcium independently predicts inci-dent premature coronary heart disease over measured cardiovas-cular risk factors: mean three-year outcomes in the Prospective Army Coronary Calcium (PACC) project. J Am Coll Cardiol. 2005; 46(5): 807-814. doi: 10.1016/j.jacc.2005.05.049

Sun Z, Ng KH. Multislice CT angiography in cardiac imag-ing. Part II: clinical applications in coronary artery disease. Sin-gapore Med J. 2010; 51(4): 282-289. Web site. http://smj.sma. org.sg/5104/5104ra2.pdf. Accessed March 30, 2016.

Alluri K, Joshi PH, Henry TS, Blumenthal RS, Nasir K, Blaha MJ. Scoring of coronary artery calcium scans: history, assumptions, current limitations, and future directions. Athero-sclerosis. 2015; 239(1): 109-117. doi: 10.1016/j.atherosclero-sis.2014.12.040

Beister M, Kolditz D, Kalender WA. Iterative reconstruc-tion methods in x-ray CT. Phys Med. 2012; 28(2): 94-108. doi: 10.1016/j.ejmp.2012.01.003

Al Shammakhi A, Sun Z. A systematic review of image quality, diagnostic value and radiation dose of coronary CT angiography using iterative reconstruction compared to filtered back projec-tion in the diagnosis of coronary artery disease. J Med Imaging Health Inf. 2015; 5(1): 96-102. doi: 10.1166/jmihi.2015.1364

Renker M, Nance JW, Schoepf UJ. Evaluation of heavily scalcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction. Ra-diology. 2011; 260(2): 390-399. doi: 10.1148/radiol.11103574

Leipsic J, Heilbron BG, Hague C. Iterative reconstruction for coronary CT angiography: finding its way. Int J Cardiovasc Im-aging. 2012; 28(3): 613-620. doi: 10.1007/s10554-011-9832-3

Ebersberger U, Tricarico F, Schoepf UJ et al. CT evalua-tion of coronary artery stents with iterative image reconstruc-tion: improvements in image quality and potential for radiation dose reduction. Eur Radiol. 2013; 23(1): 125-132. doi: 10.1007/ s00330-012-2580-5

Sun Z, Cao Y, Li HF. Multislice computed tomography angi-ography in the diagnosis of coronary artery disease. J Geriatr Car-diol. 2011; 8(2): 104-113. doi: 10.3724/SP.J.1263.2011.00104

Sun Z, Choo GH, Ng KH. Coronary CT angiography: current status and continuing challenges. Br J Radiol. 2012; 85(1013): 495-510. doi: 10.1259/bjr/15296170

Sun Z, Lin C. Diagnostic value of 320-slice coronary CT angiography in coronary artery disease: A systematic review and meta-analysis. Curr Med Imaging Rev. 2014; 10(4): 272- 280. Web site. http://www.ingentaconnect.com/content/ben/ cmir/2014/00000010/00000004/art00008. Accessed March 30, 2016

Sun Z. Cardiac CT. Imaging in coronary artery disease: current status and future directions. Quant Imaging Med Surg. 2012; 2(2): 98-105. doi: 10.3978/j.issn.2223-4292.2012.05.02

Pelliccia F, Pasceri V, Evangelista A, et al. Diagnostic ac-curacy of 320-row computed tomography as compared with in-vasive coronary angiography in unselected, consecutive patients with suspected coronary artery disease. Int J Cardiovasc Imag-ing. 2013; 29(2): 443-452. doi: 10.1007/s10554-012-0095-4

Sun Z, Lin CH, Davidson R, Dong C, Liao Y. Diagnostic val-ue of 64-slice CT angiography in coronary artery disease: A sys-tematic review. Eur J Radiol. 2008; 67(1): 78-84. doi: 10.1016/j. ejrad.2007.07.014

Meijs MFL, Meijboom WB, Prokop M, et al. Is there a role for CT coronary angiography in patients with symptomatic an-gina? Effect of coronary calcium score on identification of ste-nosis. Int J Cardiovasc Imaging. 2008; 25(8): 847-854. doi: 10.1007/s10554-009-9485-7

Meng L, Cui L, Cheng Y, et al. Effect of heart rate and coro-nary calcification on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary artery disease. Korean J Radiol. 2009; 10(4): 347-354. doi: 10.3348/kjr.2009.10.4.347

Park MJ, Jung JI, Choi YS, et al. Coronary CT angiography in patients with high calcium score: evaluation of plaque char-acteristics and diagnostic accuracy. Int J Cardiovasc Imaging. 2011; 27(2): 43-51. doi: 10.1007/s10554-011-9970-7

Vavere AL, Arbab-Zadeh A, Rochitte CE, et al. Coronary artery stenoses: accuracy of 64-detector row CT angiography in segments with mild, moderate, or severe calcification–a sub analysis of the CORE-64 trial. Radiology. 2011; 261(1): 100- 108. doi: 10.1148/radiol.11110537

Tanaka R, Yoshioka K, Muranaka K, et al. Improved evalu-ation of calcified segments on coronary CT angiography: a fea-sibility study of coronary calcium subtraction. Int J Cardiovasc Imaging. 2013; 29(2): 75-81. doi: 10.1007/s10554-013-0316-5

Sun Z, Ng C. High calcium scores in coronary CT angiogra-phy: effects of image post-processing on visualization and mea-surement of coronary lumen diameter. J Med Imaging Health Inf. 2015; 5(1): 110-116. doi: 10.1166/jmihi.2015.1366

Sun Z, Ng KC, Xu L, Fan Z, Lei J. Coronary CT angiogra-phy in heavily calcified coronary arteries: Improvement of coro-nary lumen visualization and coronary stenosis assessment with image post processing methods. Medicine. 2015; 94(48): e2148. doi: 10.1097/MD.0000000000002148

Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA. Di-agnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol. 2005; 46(3): 552-557. doi: 10.1016/j.jacc.2005.05.056

Zhang LJ, Wu SY, Wang J, et al. Diagnostic accuracy of dual-source CT coronary angiography: the effect of av-erage heart rate, heart rate variability, and calcium score in a clinical perspective. Acta Radiol. 2010; 51(7): 727-740. doi: 10.3109/02841851.2010.492792

Naoum C, Blanke P, Leipsic J. Iterative reconstruction in cardiac CT. J Cardiovasc Comput Tomogr. 2015; 9(4): 255- 263. doi: 10.1016/j.jcct.2015.04.004

Funabashi N, Irie R, Aiba M et al. Adaptive-iterative-dose re-duction 3D with multi sector-reconstruction method in 320-slice CT may maintain accurate-measurement of the Agatston-calci-um-score of severe-calcification even at higher pulsating-beats and low tube-current in vitro. Int J Cardiol. 2013; 168(1): 601- 603. doi: 10.1016/j.ijcard.2013.01.230

Blobel J, Mews J, Schuijf JD et al. Determining the radia-tion dose reduction potential for coronary calcium scanning with computed tomography: an anthropomorphic phantom study com-paring filtered back projection and the adaptive iterative dose re-duction algorithm for image reconstruction. Invest Radiol. 2013; 48(12): 857-862. doi: 10.1097/RLI.0b013e31829e3932

Matsuura N, Urashima M, Fukumoto W, et al. Radiation dose reduction at coronary artery calcium scoring by using a low tube current technique and hybrid iterative reconstruction. J Comput Assist Tomogr. 2015; 39(1): 119-124. doi: 10.1097/ RCT.0000000000000168

Hecht HS, de Siqueira MEM, Cham M, et al. Low- vs. stan-dard coronary artery calcium scanning. Eur Heart J Cardiovasc Imaging. 2015; 16(4): 358-363. doi: 10.1093/ehjci/jeu218

Schindler A, Vliegenthart R, Schoepf UJ, et al. Iterative im-age reconstruction techniques for CT coronary artery calcium quantification: comparison with traditional filtered back projec-tion in vitro and in vivo. Radiology. 2014; 270(2): 387-393. doi: 10.1148/radiol.1313023

vanOsch JAC, Mouden M, van Dalen JA, et al. Influence of iterative image reconstruction on CT-based calcium score mea-surements. Int J Cardiovasc Imaging. 2014; 30(5): 961-967. doi: 10.1007/s10554-014-0409-9

Kurata A, Dharampal A, DedicA et al. Impact of iterative re-construction on CT coronary calcium quantification. Eur Radiol. 2013; 23(12): 3246-3252. doi: 10.1007/s00330-013-3022-8

Gebhard C, Fiechter M, Fuchs TA. Coronary artery calcium score influence of adaptive statistical iterative reconstruction using 64 MDCT. Int J Cardiol. 2013; 167(6): 2932-2937. doi: 10.1016/j.ijcard.2012.08.003

Takahashi M, Kimura F, Umezawa T, Watanabe Y, Ogawa H. Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques in quantifying coronary calcium. J Cardiovasc Comput Tomogr. 2016; 10(1): 61-68. doi: 10.1016/j.jcct.2015.07.012

Obmann VC, Klink T, Heverhagen JT, et al. Impact of hybrid iterative reconstruction on Agatston coronary artery calcium scores in comparison to filtered back projection in native cardiac CT. Rofo. 2015; 187(5): 372-379. doi: 10.1055/s-0034-1398850

Willemink MJ, den Harder AM, Foppen W, et al. Finding the optimal dose reduction and iterative reconstruction level for coronary calcium scoring. J Cardiovasc Comput Tomogr. 2016; 10(1): 69-75. doi: 10.1016/j.jcct.2015.08.004

Szilveszter B, Elzomor H, Karolyi M, et al. The effect of iter-ative model reconstruction on coronary calcium quantification. Int J Cardiovasc Imaging. 2016; 32(1): 153-160. doi: 10.1007/ s10554-015-0740-9

Willemink MJ, Vliegenthart R, Takx RA, et al. Coronary ar-tery calcification scoring with state-of-the-art CT scanners from different vendors has substantial effect on risk classification. Ra-diology. 2014; 273(2): 695-702. doi: 10.1148/radiol.14140066 Heart Res Open J Page 143

Downloads

Published

2016-04-25

How to Cite

Zhonghua Sun. (2016). Effects of Iterative Reconstruction on the Diagnostic Assessment of Coronary Calcium Scores. Heart Research, 2(5), 137–143. https://doi.org/10.17140/HROJ-2-125

Most read articles by the same author(s)