Diagnostic Value of Coronary CT Angiography With Use of Left Coronary Bifurcation Angle in Coronary Artery Disease
DOI:
https://doi.org/10.17140/HROJ-3-131Keywords:
Bifurcation angle; Coronary artery disease, Coronary CT angiography, Coronary plaque; Measurement.Abstract
Background: Atherosclerosis generally occurs in the blood vessels with angulation or curvature,
however, association between coronary bifurcation angle and coronary artery disease
needs to be further clarified when compared to normal patients.
Objectives: The aim of this study is to determine the relationship between left coronary bifurcation
angle and development of coronary artery disease when compared to patients with normal
coronary arteries.
Methods: Fifty patients (40 men, mean age, 55.2 years) who underwent coronary computed
tomography (CT) angiography for clinical diagnosis of coronary artery disease were included
in the study. Of these patients, coronary plaques were present at one or more coronary arteries
in 25 patients, while in the remaining 25 cases, no plaque was detected at the coronary arteries,
thus serving as the control group. Left coronary bifurcation angle between left anterior
descending and left circumflex was measured on 3D volume rendering images by two assessors
with >80º as the cut-off value to determine significant stenosis.
Results: The mean bifurcation angle was 72.9º±19.4º (range, 36º, 112º) among 50 patients.
The mean bifurcation angle was significantly wider in patients with coronary plaques than that
measured in patients with normal coronary artery (p<0.001), with corresponding values being
83.9º±17.5º (range, 45º,112º) and 62.5º±15.4º (range, 36º, 89º). Of 25 patients with coronary
plaques, 18 (72%) had a bifurcation angle >80º, while only 12% of the patients had a bifurcation
angle >80º in the control group.
Conclusion: This study further confirms the direct relationship between left coronary bifurcation
angle and development of coronary artery disease with diseased coronary arteries associated
with wider angulation.
References
Sun Z, Cao Y, Li HF. Multislice computed tomography angi-ography in the diagnosis of coronary artery disease. J Geriatr Cardiol. 2011; 8: 104-113. doi: 10.3724/SP.J.1263.2011.00104
Sun Z, Choo GH, Ng KH. Coronary CT angiography: Current status and continuing challenges. Br J Radiol. 2012; 85: 495- 510. doi: 10.1259/bjr/15296170
Sun Z, Lin C. Diagnostic value of 320-slice coronary CT angiography in coronary artery disease: A systematic review and meta-analysis. Curr Med Imaging Rev. 2014; 10: 272- 280. Web site. http://www.ingentaconnect.com/content/ben/ cmir/2014/00000010/00000004/art00008. Accessed August 18, 2016
Pelliccia F, Pasceri V, Evangelista A, et al. Diagnostic accura-cy of 320-row computed tomography as compared with invasive coronary angiography in unselected, consecutive patients with suspected coronary artery disease. Int J Cardiovasc Imaging. 2013; 29: 443-452. doi: 10.1007/s10554-012-0095-4
Funabashi N, Namihira Y, Irie R, et al. Recommended acqui-sition parameters in achieving successful evaluation of coronary lumen patency surrounded by XIENCE of diameters <3.0 mm in 2nd-generation 320-slice CT. XIENCEPhantom Study part 2. Int J Cardiol. 2016; 202: 541-545. doi: 10.1016/j.ijcard.2015.09.038
Zhang LJ, Wu SY, Wang J, et al. Diagnostic accuracy of dual-source CT coronary angiography: The effect of aver-age heart rate, heart rate variability, and calcium score in a clinical perspective. Acta Radiol. 2010; 51: 727-740. doi: 10.3109/02841851.2010.492792
Tomizawa N, Maeda E, Akahane M, Torigoe R, Kiryu S, Ohtomo K. Coronary CT angiography using the second-gen-eration 320-detector row CT: Assessment of image qualityand radiation dose in various heart rates compared with the first-gen-eration scanner. Int J Cardiovasc Imaging. 2013; 29: 1613-1618. doi: 10.1007/s10554-013-0238-2
Wong DT, Soh SY, Ko BS, et al. Superior CT coronary an-giography image quality at lower radiation exposure with sec-ond generation 320-detector row CT in patients with elevated heart rate: A comparison with first generation 320-detector row CT. Cardiovasc Diagn Ther. 2014; 4: 299-306. doi: 10.3978/j. issn.2223-3652.2014.08.05
Latif MA, Sanchez FW, Sayegh K, et al. Volumetric single-beat coronary computed tomography angiography: Relationship of image quality, heart rate, and body mass index. Initial patient experience with a new computed tomography scanner. J Comput Assist Tomogr. 2016. doi: 10.1097/RCT.0000000000000428
Ghekiere O, Nchimi A, Djekic J, et al. Coronary computed to-mography angiography: patient-related factors determining im-age quality using a second-generation 320-slice CT scanner. Int J Cardiol. 2016; 221: 970-976. doi: 10.1016/j.ijcard.2016.07.141
Meng L, Cui L, Cheng Y, et al. Effect of heart rate and coro-nary calcification on the diagnostic accuracy of the dual-source CT coronary angiography in patients with suspected coronary ar-tery disease. Korean J Radiol. 2009; 10: 347-354. doi: 10.3348/ kjr.2009.10.4.347
Park MJ, Jung JI, Choi YS, et al. Coronary CT angiography in patients with high calcium score: Evaluation of plaque char-acteristics and diagnostic accuracy. Int J Cardiovasc Imaging. 2011; 27: 43-51. doi: 10.1007/s10554-011-9970-7
Vavere AL, Arbab-Zadeh A, Rochitte CE, et al. Coronary artery stenoses: Accuracy of64-detector row CT angiography in segments with mild, moderate, or severe calcification-a subanal-ysis of the CORE-64 trial. Radiology. 2011; 261: 100-108. doi: 10.1148/radiol.11110537
Chen CC, Chen CC, Hsieh IC, et al. The effect of calcium score on the diagnostic accuracy of coronary computed tomog-raphy angiography. Int J Cardiovasc Imaging. 2011; 37-42. doi: 10.1007/s10554-011-9955-6
Palumbo A, Maffei E, Martini C, et al. Coronary calcium score as gatekeeper for 64-slice computed tomography coronary angiography in patients with chest pain: per-segment and per-patient analysis. Eur Radiol. 2009; 19: 2127-2135. doi: 10.1007/ s00330-009-1398-2
Tanaka R, Yoshioka K, Muranaka K, et al. Improved evalu-ation of calcified segments on coronary CT angiography: A fea-sibility study of coronary calcium subtraction. Int J Cardiovasc Imaging. 2013; 29: 75-81. doi: 10.1007/s10554-013-0316-5
Sun Z, Ng C. High calcium scores in coronary CT angiogra-phy: Effects of image post-processing on visualization and mea-surement of coronary lumen diameter. J Med Imaging Health Inf. 2015; 5: 110-116. doi: 10.1166/jmihi.2015.1366
Sun Z, Ng KC, Xu L, Fan Z, Lei J. Coronary CT angiogra-phy in heavily calcified coronary arteries: Improvement of coro-nary lumen visualization and coronary stenosis assessment with image post-processing methods. Medicine. 2015; 94: e2148. doi: 10.1097/MD.0000000000002148
Sun Z, Xu L, Fan Z. Coronary CT angiography in calcified coronary plaques: Comparison of diagnostic accuracy between bifurcation angle measurement and coronary lumen assessment for diagnosing significant coronary stenosis. Int J Cardiol. 2016; 203: 78-86. doi: 10.1016/j.ijcard.2015.10.079
Xu L, Sun Z. Coronary CT angiography evaluation of calci-fied coronary plaques by measurement of left coronary bifurca-tion angle. Int J Cardiol. 2015; 182: 229-231. doi: 10.1016/j. ijcard.2014.12.114
Sun Z. Coronary CT angiography in coronary artery disease: Correlation between virtual intravascular endoscopic appearanc-es and left bifurcation angulation and coronary plaques. Biomed Res Int. 2013; 2013: 732059. doi: 10.1155/2013/732059
Sun Z, Dimpudus FJ, Nugroho J, Adipranoto JD. CT virtual intravascular endoscopy assessment of coronary artery plaques: A preliminary study. Eur J Radiol. 2010; 75: e112-e119. doi: 10.1016/j.ejrad.2009.09.007
Xu L, Sun Z. Virtual intravascular endoscopy visualization of calcified coronary plaques: A novel approach of identify-ing plaque features for more accurate assessment of coronary lumen stenosis. Medicine. 2015; 94(17): e805. doi: 10.1097/ MD.0000000000000805
Chaichana T, Sun Z, Jewkes J. Computation of hemodynamics in the left coronary artery with variable angulations. J Biomech. 2011; 44: 1869-1878. doi: 10.1016/j.jbiomech.2011.04.033
Markl M, Wegent F, Zech T, et al. In vivo wall shear stress distribution in the carotid artery: Effect of bifurcation geometry, internal carotid artery stenosis, and recanalization therapy. Circ Cardiovasc Imaging. 2010; 3: 647-655. doi: 10.1161/CIRCIM-AGING.110.958504
Arjmandi Tash O, Razavi SE. Numerical investigation of pulsatile blood flow in a bifurcation model with a non-planar branch: The effect of different bifurcation angles and non-planar branch. Bioimpacts. 2012; 2: 195-205. doi: 10.5681/bi.2012.023
Rodriguez-Granillo GA, Garcia-Garcia HM, Wentzel J, et al. Plaque composition and its relationship with acknowledged shear stress patterns in coronary arteries. J Am Coll Cardiol. 2006; 47: 884-885. doi: 10.1016/j.jacc.2005.11.027
Park JB, Choi G, Chun EJ, et al. Computational fluid dynam-ic measures of wall shear stress are related to coronary lesion characteristics. Heart. 2016. doi: 10.1136/heartjnl-2016-309299
Pang CL, Alcock R, Pilkington N, Reis T, Roobottom C. Determining the haemodynamic significance of arterial stenosis: The relationship between CT angiography, computational fluid dynamics, and non-invasive fractional flow reserve. Clin Radiol. 2016; 71: 750-757. doi: 10.1016/j.crad.2016.03.001
Sun Z, Cao Y. Multislice CT angiography assessment of left coronary artery: Correlation between bifurcation angle, dimen-sions and development of coronary artery disease. Eur J Radiol. 2011; 79: e90-e95. doi: 10.1016/j.ejrad.2011.04.015
Temov K, Sun Z. Coronary computed tomography angiogra-phy investigation of the association between left main coronary artery bifurcation angle and risk factors of coronary artery dis-ease. Int J Cardiovasc Imaging. 2016; 32(Suppl 1): S129-S137. doi: 10.1007/s10554-016-0884-2
Tesche C, De Cecco CN, Caruso D, et al. Coronary CT angiography derived morphological and functional quantita-tive plaque markers correlated with invasive fractional flow reserve for detecting hemodynamically significant stenosis. J Cardiovasc Comput Tomogr. 2016; 10: 199-206. doi: 10.1016/j. jcct.2016.03.002
Downloads
Published
How to Cite
Issue
Section
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
All content published in Heart Research (HROJ) is licensed under the Creative Commons Attribution 4.0 International License (CC BY 4.0). This license allows anyone to copy, distribute, transmit, and adapt the work — including for commercial purposes — provided appropriate credit is given to the original author(s) and source.